✨ New Arrivals Just Dropped!Explore
TOOLTOP X5 400A AC DC Clamp Meter 6000 Counts True RMS Multimeter NCV Current Voltage Hz Diode Temp Buzzer Test Auto Ammeter
HomeStore

TOOLTOP X5 400A AC DC Clamp Meter 6000 Counts True RMS Multimeter NCV Current Voltage Hz Diode Temp Buzzer Test Auto Ammeter

TOOLTOP X5 400A AC DC Clamp Meter 6000 Counts True RMS Multimeter NCV Current Voltage Hz Diode Temp Buzzer Test Auto Ammeter

$6.44

Original: $21.47

-70%
TOOLTOP X5 400A AC DC Clamp Meter 6000 Counts True RMS Multimeter NCV Current Voltage Hz Diode Temp Buzzer Test Auto Ammeter

$21.47

$6.44

The Story

Features:
  • 1.Large Color Screen 3 Line Display
  • 2.Automatic Measurement Function
  • 3.NCV Function
  • 4.Flashlight Function
  • 5.Multi-function Test: AC DC Voltage/AC DC Current/Temperature/Frequency /Capacitance/Resistance/Line On/Off/Diode Measurement

Specification:

  • Model: X5
  • AC current:400A
  • DC current: Maximum: 400A Minimum: 200mA
  • DC voltage: 600V
  • AC voltage: 600V
  • Resistance: 600MΩ
  • Capacitor: 60.00mF
  • Temperature:-40~1000°C/-40~1832°F
  • Frequency: 60.0Hz 1000Hz
  • DIODE: 1V
  • NCV√
  • Live√
  • AC voltage measurement√
  • Line on-off test:
  • Automatic identification√
  • Automatic measurement√
  • Overload protection√
  • Operating height: Max. 2000m
  • Display: LCD
  • Max. display value: 6000 digit
  • Polarity indication: Automatic indication, and '-'indicates negative.
  • Over range display: 'OL'or'-OL'
  • Sampling time: About 3 times/second., bargraph 10 times/second
  • Unit display: Function and electricity quantity unit display
  • Automatic shutdown:< (15 minutes)
  • Power supply: 1.5VAAA battery x 2(not included)
  • Temperature coefficient : Less than 0.1x accuracy/°C
  • Operating temperature: 18°C~28°C
  • Storage temperature: -10°C~50°C
  • Net weight ≈157g
  • Packed weight ≈279g
  • Accessories: Test Leads x 1, Use Manual x 1, K-Type x 1
 
Note: When testing DC current, you need to stay away from the object being measured. Press the REL key to clear it, and then clamp into the object being measured. The measured voltage cannot exceed the range allowed by the instruction manual.

Package List:

  • 1 * Clamp Meter
  • 1 * User Manual
  • 1 * K-Type Thermocouple
  • 1 * Test Leads
TOOLTOP X5 400A AC DC Clamp Meter 6000 Counts True RMS Multimeter NCV Current Voltage Hz Diode Temp Buzzer Test Auto Ammeter - Image 2

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

TOOLTOP X5 400A AC DC Clamp Meter 6000 Counts True RMS Multimeter NCV Current Voltage Hz Diode Temp Buzzer Test Auto Ammeter - Image 3

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

TOOLTOP X5 400A AC DC Clamp Meter 6000 Counts True RMS Multimeter NCV Current Voltage Hz Diode Temp Buzzer Test Auto Ammeter - Image 4

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

TOOLTOP X5 400A AC DC Clamp Meter 6000 Counts True RMS Multimeter NCV Current Voltage Hz Diode Temp Buzzer Test Auto Ammeter - Image 5

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

TOOLTOP X5 400A AC DC Clamp Meter 6000 Counts True RMS Multimeter NCV Current Voltage Hz Diode Temp Buzzer Test Auto Ammeter - Image 6

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Description

Features:
  • 1.Large Color Screen 3 Line Display
  • 2.Automatic Measurement Function
  • 3.NCV Function
  • 4.Flashlight Function
  • 5.Multi-function Test: AC DC Voltage/AC DC Current/Temperature/Frequency /Capacitance/Resistance/Line On/Off/Diode Measurement

Specification:

  • Model: X5
  • AC current:400A
  • DC current: Maximum: 400A Minimum: 200mA
  • DC voltage: 600V
  • AC voltage: 600V
  • Resistance: 600MΩ
  • Capacitor: 60.00mF
  • Temperature:-40~1000°C/-40~1832°F
  • Frequency: 60.0Hz 1000Hz
  • DIODE: 1V
  • NCV√
  • Live√
  • AC voltage measurement√
  • Line on-off test:
  • Automatic identification√
  • Automatic measurement√
  • Overload protection√
  • Operating height: Max. 2000m
  • Display: LCD
  • Max. display value: 6000 digit
  • Polarity indication: Automatic indication, and '-'indicates negative.
  • Over range display: 'OL'or'-OL'
  • Sampling time: About 3 times/second., bargraph 10 times/second
  • Unit display: Function and electricity quantity unit display
  • Automatic shutdown:< (15 minutes)
  • Power supply: 1.5VAAA battery x 2(not included)
  • Temperature coefficient : Less than 0.1x accuracy/°C
  • Operating temperature: 18°C~28°C
  • Storage temperature: -10°C~50°C
  • Net weight ≈157g
  • Packed weight ≈279g
  • Accessories: Test Leads x 1, Use Manual x 1, K-Type x 1
 
Note: When testing DC current, you need to stay away from the object being measured. Press the REL key to clear it, and then clamp into the object being measured. The measured voltage cannot exceed the range allowed by the instruction manual.

Package List:

  • 1 * Clamp Meter
  • 1 * User Manual
  • 1 * K-Type Thermocouple
  • 1 * Test Leads